Drosophila Chambers - DR-36NL

These chambers have been specifically designed from rearing drosophila, (fruit flies.) Additive humidity and Phenolic coated coils come standard to provide the best environment for your drosophilia rearing.

Adobe AcrobatDownload a PDF of this product.
Arabidopsis Chamber - AR36VL

Model

Temp
Range
Lights On

Interior Space
(volume)

Work Area

Maximum Growing Height

Exterior Dimension
in (cm)

Light Intensity
6” from lamp

# of Tiers

 

ºC

ft3

m3

ft2

m2

in

cm

(W)

(D)

(H)

µmoles/m2 /s

 

I-36VL

4-44 +/-0.5

29.7

0.8

23.6

2.2

9.5

24.1

33.5

33.6

85.4

80

5

Door

One door opening 29.2" x 57.5" provides full access to the chamber interior. A magnetic gasket provides a tight seal to door frame.

Lighting

Four 32W fluorescent lamps mounted vertically on each side of shelf. Intensity is adjustable up to 80 µmoles/m2/s of light irradiance measured @ 6" from the lamps. Programming and control of the lighting is done via Intellus real time controller.

Insulation

Woodless construction using CFC free insulation. Overall wall thickness is 2" (5.1 cm), ample insulation for maintenance of stated temperature range.

Interior Space

29.7 ft3 (0.8 m3) with a work area 23.6 ft2 (2.2 m2) provided on five tiers.

Shelving

Five tiers of white epoxy coated steel wire shelving. Each shelf is 27" D x 25.2" W. Shelves are supported by shelf clips which allows 1/2" vertical adjustments.

Coils

Phenolic Coated Coils are provided to protect coils from acidic secretion from drosophila.

Refrigeration

1/4 h.p. self-contained air-cooled condensing unit with hot gas bypass system for continuous compressor operation, extended life and close temperature control. This continuous running condensing unit ensures precise temperature control by alternately cycling refrigerant and hot gas to the coil; this also prolongs the life of the compressor, and eliminates the risk of ice build up in the coil. Top mounted refrigeration system allows easy access for maintenance (e.g. cleaning). Also, as heat is rejected, it rises and is dissipated into the room without having any effect on the inside temperature cabinet. Solenoid valves have an extended stem for quiet and long life operation. Evaporator coil is ceiling mounted and incorporates twin air circulation fans in an aluminum housing. Heat rejection to ambient (standard chamber) =3500 BTU/hr.

Temperature Range

4° - 44° C lights on (± 0.5° C) and 2° - 44° C lights off ( ± 0.5° C).

Airflow

The conditioned air circulates through a rear wall perforated diffuser and travels horizontally across the shelving work area.

Humidity Control (Included)

Additive humidity control of higher than ambient to 85% (lights on or off) for temperatures between 15° to 30° C. A Humidifier requires distilled or demineralized water. Optional dehumidification via independent dehumidifying coil and reheat heaters will maintain humidity levels down to 40% between 15° to 30° C. Humidity control ± 10% with Humichip Electric Sensor and ± 5% with Advanced Sensor. Additional humidity ranges available.

Convenience Receptacles

One 115/1/60 convenience receptacle provided inside chamber.

Electrical Requirements

115/1/60 - Contact Geneva Scientific for amerage draw. Power cords and grounded plugs provided.

*specications subject to change without notice*

©2006 GENEVA SCIENTIFIC ALL RIGHTS RESERVED | Internet Marketing by Atlantic BT