Our Biological Safety Cabinets are containment units suitable for the preparation of low to moderate risk agents when there is a need for protection of the product, personnel, and environment. We offer a ranges of cabinets depending on the researchers needs and budged.
All biological safety cabinets use ULPA filters to treat exhaust air. ULPA filters have are tested to a typical effiecency of >99.999% for 0.1 to 0.3 micron particles; these provide better filtration capability than conventional HEPA filters that have a typical efficiency of >99.999% for 0.3 micron particles.
Compare your requirements below to find the correct Biological Safety Cabinet for your lab.
| Specifications | GBS-3F-TIIA2 | GBS-4F-TIIA2 | GBS-5F-TIIA2 | GBS-6F-TIIA2 | |
| Add to Quote | Add to Quote | Add to Quote | Add to Quote | ||
| External Dimensions (W x D x H) | 43.9" x 31.9" x 60.6" 1115 x 810 x 1540 mm |
55.9" x 32.1" x 64.6" 1420 x 815 x 1640 mm |
67.9" x 32.1" x 60.6" 1725 x 815 x 1540 mm |
79.9" x 32.1" x 64.6" 2030 x 815 x 1640 mm |
|
| Gross Internal Dimensions (W x D x H) | 37.6" x 24.5" x 26.4" 955 x 623 x 670 mm |
49.6" x 24.5" x 28.1" 1260 x 623 x 715 mm |
61.6" x 24.5" x 26.4" 1565 x 623 x 670 mm |
73.6" x 24.5" x 28.1" 1870 x 623 x 715 mm |
|
| Work Area | 4.8 sq.ft. (0.45 m2 ) | 6.5 sq.ft. (0.6 m2) | 8.1 sq.ft. (0.75 m2 ) | 9.7 sq.ft. (0.9 m2 ) | |
| Working Opening | 10.8" (274 mm) | 10.8" (274 mm ) | 10.8" 274 mm | 9.8" (248 mm) | |
| Average Airflow Velocity | Inflow | 0.53 m/s (105 fpm) | |||
| Downflow | 0.35 m/s (70 fpm) | 0.35 m/s (70 fpm) | 0.35 m/s (70 fpm) | 0.33 m/s (65 fpm) | |
| Airflow Volume | Inflow | 419 m3 / h (246 cfm) | 552 m3 / h (325 cfm) | 685 m3 / h (403 cfm) | 724 m3 / h (426 cfm) |
Downflow 63% Recriculating |
702 m3 / h (413 cfm) | 924 m3 / h (544 cfm) | 1147 m3 / h (675 cfm) | 1289 m3 / h (758 cfm) | |
Exhaust, 37% Exhaust |
419 m3 / h (246 cfm) | 552 m3 / h (325 cfm) | 685 m3 / h (403 cfm) | 724 m3 / h (426 cfm) | |
| Required Exhaust With Optional Thimble Exhaust Collar | 707 m3 / h (416 cfm) | 901 m3 / h (530 cfm) | 1114 m3 / h (656 cfm) | 1256 m3 / h (739 cfm) | |
| Sound Emission* | NSF / ANSI 49 | >63 dBA | >61.5 dBA | >63 dBA | >64 dBA |
| EN 12469 | >60 dBA | >58.5 dBA | >60 dBA | >61 dBA | |
| Fluorescent Lamp Intensity | > 1230 Lux (> 114 foot-candles) | > 1400 Lux (> 130 foot-candles) | > 1070 Lux (> 100 foot-candles) | > 1225 Lux (> 114 foot-candles) | |
| Cabinet Construction | External | Electrogalvanized steel with Isocide oven-baked epoxy-polyester powder coating | |||
| Internal | 1.2 mm (0.05") /18 gauge | 1.5 mm (0.06") /16 gauge | 1.2 mm (0.05") /18 gauge | 1.5 mm (0.06") /16 gauge | |
| Standards Compliance | Biosafety Cabinets | Air Quality | Filtration | Electrical Safety |
| NSF / ANSI 49, USA* EN 12469, Europe JIS K 3800, Japan SFDA YY-0569, China |
ISO 14644.1, Class 3, Worldwide JIS B9920, Class 3, Japan JIS BS5295, Class 3, Japan US Fed Std 209E, Class 1 USA |
EN-1822 (H14), Europe IEST-RP-CC001.3, USA IEST-RP-CC007, USA IEST-RP-CC034.1, USA |
UL-C-61010A-1, USA CSA22.2, No.1010-192, Canada EN-61010-1, Europe IEC61010-1, Worldwide |