Class II, Type A2 Biological Safety Cabinet; R-Series

Our Biological Safety Cabinets are containment units suitable for the preparation of low to moderate risk agents when there is a need for protection of the product, personnel, and environment. We offer a ranges of cabinets depending on the researchers needs and budged.

All biological safety cabinets use ULPA filters to treat exhaust air. ULPA filters have are tested to a typical effiecency of >99.999% for 0.1 to 0.3 micron particles; these provide better filtration capability than conventional HEPA filters that have a typical efficiency of >99.999% for 0.3 micron particles.

Compare your requirements below to find the correct Biological Safety Cabinet for your lab.

Specifications GRBS-4F-TIIA2 GRBS-6F-TIIA2
Add to Quote Add to Quote
External Dimensions(W x D x H)

52.8" x 30" x 56.7"

76.8" x 30" x 60.6"
Gross Internal Dimensions(W x D x H) 50.0” x 21.5” x 26.8” 72.0” x 21.5” x 26.8”
Work Area 5.4 sq ft (0.50 m2) 8.1 sq.ft. (0.75 m2 )
Working Opening 10.4" 264 mm 8.4" 213 mm
Average Airflow Velocity Inflow 0.53 m/s (105 fpm)
Downflow 0.35 m/s (70 fpm) 0.33 m/s (65 fpm)
Airflow Volume Inflow 591 m3 / h (350 cfm) 708 m3 / h (420 cfm)
Downflow 851 m3 / h (509 cfm) 1204 m3 / h (763 cfm)
Exhaust 591 m3 / h (350 cfm) 708 m3 / h (420 cfm)
Required 785 m3 / h (462 cfm) 953 m3 / h (561 cfm)
Exhaust With Optional Thimble Exhaust Collar 785 m3 / h (462 cfm) 953 m3 / h (561 cfm)
Sound Emission* NSF / ANSI 49 <63 dBA <62 dBA
EN 12469 <60 dBA <59 dBA
Fluorescent Lamp Intensity > 1076 Lux (> 100 foot-candles)
Cabinet Construction Main Body Electrogalvanized steel with Isocide oven-baked epoxy-polyester powder coating
Work Zone and Sides 1.2 mm (0.05") / 18 gauge stainless steel, type 304, with 4B finish

Containment and Protection

  • The airflow ratio of 63% recirculation to 37% exhaust increases operator protection beyond the 70%/30% ratio of conventional biological safety cabinets.
  • The inflow and downflow balance is precisely established by an external exhaust damper and is adjustable without decontaminating the biosafety cabinet.
  • Inflow of room air enters the front air grille to establish operator protection; room air does not enter the work zone, preventing product contamination.
  • The front grille has proportionally larger perforations on the extreme left and right side. Combined with the side air gap between the work tray and the side wall, the stronger side capture zones increase protection in this critical area where contaminants tend to bleed out in conventional cabinets.
  • The convex inflow grille maintains operator protection by discouraging users from placing objects on it.
  • Auto-purge holes located at the front side walls eliminate eddy currents and dead air pockets in the critical area behind the sash window. Per NSF/ANSI 49 requirement, these side perforations do not extend completely to the work surface to prevent accidental liquid spills in the work zone from entering the side air column.

Integrated Filtration System

  • A combination of a supply ULPA filter and an exhaust ULPA filter give the biosafety cabinet a fully integrated performance envelope for product, operator and environmental protection.
  • ULPA filters (per IEST-RP-CC001.3), are tested to a typical efficiency of >99.999% for 0.1 to 0.3 micron particles; these provide better filtration capability than conventional HEPA filters that have a typical efficiency of >99.99% for 0.3 micron particles.
  • Modern separator-less mini-pleat filter construction maximizes the filer surface area to extend filter life and eliminate possible filter media damage by thin and sharp aluminum separators used in conventional HEPA filter construction.
  • The filter frame and media is constructed in accordance with EN 1822 requirements for fire retardant properties.
  • The supply ULPA filter provides ISO Class 3 (per ISO 14644.1) clean air to the work surface in a gentle vertical laminar flow for product protection.
  • The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection.
  • The exhaust filter media is protected from mechanical damage by an integrated metal screen guard, which is absent from convention HEPA filters.
  • The top cabinet surface is slanted to discourage users from placing objects which could block the exhaust filter and reduce inflow velocity.

Front Sash Assembly

  • Integrated sash proximity contacts sense proper sash position, serve as an interlock for the UV lamp, and activate an alarm if the sash is improperly positioned.
  • The magnetic switch eliminates the chance of wear and tear typical of a mechanical switch.
  • The back of the sash can be easily cleaned by removing the sash track cover and swinging up the sash glass.
  • The sash is counterbalanced for smooth, lightweight operation.
  • The counterbalance locking mechanism is inherently safe; it locks the counter balance in place if either of the 2 cables is detached. the sash cable and cable clip have rated strength of more than 6 times he weight of the sash window of the largest cabinet. (6ft.)
  • The safety glass maintains containment if the sash is accidentally broken during cabinet operation.

Blower Efficiency

  • The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance.
  • German made ebm-papst® permanently lubricated, centrifugal motor/blowers with external rotor designs.
  • Motors are selected for energy efficiency, compact design, and flat profile. Completely integrated assembly optimizes motor cooling.
  • All rotating parts are balanced for smooth, quiet, vibration-free operation.

Controller

Reliable rocker switches and easy-to-read Minihelic gauge for safety and durability work.


Airflow

  • "Blue Arrows" ULPA-Filtered Air
  • "Red Arrows" Unfiltered / Potentially contaminated Air
  • "Green Arrows" Room Air / Inflow Air

  • Ambient air is pulled through the perforations located towards the work zone front to prevent contamination of the work surface and work product. The inflow does not mix with the clean air within the cabinet work zone. Inflow air travels through a return path toward the common air plenum (blower plenum) at the top of the cabinet.
  • Approximately 40% of the air in the common plenum is exhausted through the ULPA filter to the room. The remaining 65% of the air is passed through the downflow ULPA filter and into the work area as a vertical laminar flow air stream bathing the work surface in clean air.
  • The uniform, non-turbulent air stream protects against cross contamination within and throughout the work area.
  • Near the work surface, the downflow air stream splits with a portion moving toward the front air grille, and the remainder moving to the rear air grille. A small portion of the ULPA filtered downflow enters the intake perforations at the side capture zones at a higher velocity (small blue arrows).
  • A combination of inflow and downflow air streams forms an air barrier that prevents contaminated room air from entering the work zone, and prevents work surface emissions from escaping the work zone.
  • Air returns to the common air plenum where the 40% exhaust and 60% recirculation process is continued.
  •  



    Cabinet Construction

    • Robust construction and enhanced safety features qualify the biological safety cabinet for the most demanding laboratory applications. The biological safety cabinet is fully assembled and ready to install and operate when shipped.
    • Key components, including fluorescent lamps, motor capacitor, electrical harness, electronic ballast, and switch control are mounted outside the airstream and away from contaminated air to permit service without decontamination. Single-piece stainless-steel work tray and front grille, lower drain pan with angled side, and single-piece work zone liner eliminate joints for superior cleanability.
    • Unique front grill designed to provide the maximum product and personnel protection.
    • The double-wall design creates a Dynamic Chamber plenum which surrounds contaminated areas with negative pressure, preventing the possibility of contamination from leaks in filter seal, gasket or cabinet structure.
    • External surfaces are coated with IsocideTM antimicrobial coating to protect against surface contamination and inhibit bacterial growth. Isocide eliminates 99.9% of surface bacteria within 24 hours of exposure.
    • Raised one-piece work surface lifts and removes for easy surface decontamination.
    • Reliant utilizes a heavy-gauge, one-piece liner with coved corners for easy cleaning and durability.
    • Lowest height profile of any benchtop biological safety cabinet for the North American market.
    • Dual-wall construction surrounds the work zone with negative pressure plenums for maximum safety.

    Comfortable Ergonomic Design

    • The biosafety cabinet. is engineered for comfort, utility value and safety.
    • The angled viewing window and narrow profile front grille improves reach into the work area.
    • The front armrest is raised above the workzone to improve comfort and to ensure that the operator's arms do not block the forward airflow perforations.
    • The optional adjustable support stand provides work surface height control.
    • The frameless sash eliminates operator's line of sight blockage.
    • A generous sash opening allows for easier access into the work zone, provides ample room for transferring of small equipment.

    Electrical Safety and Certification

    • All components meet or exceed applicable safety requirements.
    • Each cabinet is individually tested for electrical safety at factory.
    • Documentation specific to each cabinet serial number is maintained on file.
    • UL listed for USA and Canada.
    • Certified to all major world standards for biological safety cabinets, including the NSF / ANSI 49 and EN 12469 (refer to Standards Compliance table on this page for the full list.)
    • Contact Geneva Scientific for site preparation information; see Electrical specifications.

    Warranty

    • Our biological safety cabinets are warranted for 5 years excluding consumable parts and accessories.
    • Each cabinet is shipped with a comprehensive user's manual complete with a report documenting all test procedures.
    • Additional IQ/OQ/PQ documenting is available upon request.

    Accessories and Options

    • Stands
      • Stand; 28"-30" work surface with Leveling Feet
      • Adjustable Stand with Leveling Feet; 26"-37" (28"-39" work surface)
      • Adjustable Stand with Casters; 26.5"-35.5" (28"-39" work surface)
      • Hydraulic, Motorized Adjustable Stand 25"-37" (27"-37" work surface)

    • Electrical Outlets and Utility Fixtures
      • Electrical Outlet, ground fault. (One Included)
      • Petcock (air, gas, vacuum) (One Included)

    • Cabinet Accessories
      • IV Bar, with Hooks
      • Stainless Steel construction
      • Germicidal UV Lamp -
        Controlled by automatic UV lamp timer through microprocessor control panel.
        Emission of 253.7 nanometers for most efficient decontamination.
        Lamp is positioned away from operator line-of-site for safety and proper exposure to interior surfaces. (Note: UV lamp intensity reduces over time and its effectiveness is subject to factors such as relative humidity in the biological safety cabinet, ambient air temperature and microbial species in the work zone.)
      • PV Armrest -
        Chemically treated, improves operator comfort, easy to clean. 28" (712 mm) standard size.
      • Ergonomic Lab Chair -
        Laboratory grade construction, meets Class 100 cleanliness; alcohol resistant PVC materials.
        Adjustable 15.6"-19.3"
      • Ergonomic Foot Rest-
        Angled, helps maintain proper posture
        Adjustable height
        Anti-skid coating, chemical resistant finish
      • Microscope Viewing Device
      • Mounting and viewing pouch integrated into sash
      • Exhaust Options
      • Damper
      • Air Tight Damper for all B2 & A2 cabinets. 9.75" dia. x 9.75" H. (Fits inside 10" Duct)
      • Thimble Exhaust
      • Transition for Biological Safety Cabinet to 10" Round Duct


    Standards Compliance Biosafety Cabinets Air Quality Filtration Electrical Safety
    NSF / ANSI 49, USA*
    JIS K 3800, Japan
    SFDA YY-0569, China
    ISO 14644.1, Class 3, Worldwide
    JIS B9920, Class 3, Japan
    JIS BS5295, Class 3, Japan
    US Fed Std 209E, Class 1 USA
    EN-1822 (H14), Europe
    IEST-RP-CC001.3, USA
    IEST-RP-CC007, USA
    IEST-RP-CC034.1, USA
    UL-C-61010A-1, USA
    CAN/ CSA 22.2, No. 61010-1
    EN-61010-1, Europe
    IEC61010-1, Worldwide

     