Provide protection to both lab personnel and the environment from toxic fumes

| Model | Dimensions (in.) |
Worktop (in.) |
Hood Opening (in.) |
Airflow | Add to Quote what's this? |
||||||
| W | H | D | W | H | D | W | H | CFM @ 29"* |
CFM @ 18"* |
||
AirFoil Standard Fume Hoods |
|||||||||||
| EH-111-36 | 36 | 56 | 33.3 | 36 | 1.3 | 30 | 26 | 29 | 567 | 354 | Add |
| EH-111-48 | 48 | 56 | 33.3 | 48 | 1.3 | 30 | 38 | 29 | 833 | 521 | Add |
| EH-111-60 | 60 | 56 | 33.3 | 60 | 1.3 | 30 | 50 | 29 | 1100 | 688 | Add |
| EH-111-72 | 72 | 56 | 33.3 | 72 | 1.3 | 30 | 62 | 29 | 1367 | 854 | Add |
| EH-111-96 | 93 | 56 | 33.3 | 93 | 1.3 | 30 | 86 | 29 | 1900 | 1188 | Add |
Double Faced Fume Hoods |
|||||||||||
| EH-211-36 | 36 | 56 | 35.5 | 36 | 1.3 | 29 | 26 | 29 | 567 | 354 | Add |
| EH-211-48 | 48 | 56 | 35.5 | 48 | 1.3 | 29 | 38 | 29 | 833 | 521 | Add |
| EH-211-60 | 60 | 56 | 35.5 | 60 | 1.3 | 29 | 50 | 29 | 1100 | 688 | Add |
| EH-211-72 | 72 | 56 | 35.5 | 72 | 1.3 | 29 | 62 | 29 | 1367 | 854 | Add |
| EH-211-96 | 96 | 56 | 35.5 | 96 | 1.3 | 29 | 86 | 29 | 1900 | 1188 | Add |
Walk-In Fume Hoods |
|||||||||||
| EH-411-48 | 48 | 93 | 35 | - | - | - | 38 | 72 | 990** | 1979** | Add |
| EH-411-60 | 60 | 93 | 35 | - | - | - | 50 | 72 | 1306** | 2613** | Add |
| EH-411-72 | 72 | 93 | 35 | - | - | - | 62 | 72 | 1623** | 3246** | Add |
| EH-411-96 | 96 | 93 | 35 | - | - | - | 86 | 72 | 2256** | 4513** | Add |
Perchloric Acid Fume Hoods |
|||||||||||
| EH-716-36 | 36 | 56 | 33.3 | 36 | 1.3 | 30 | 26 | 29 | 567 | 354 | Add |
| EH-716-48 | 48 | 56 | 33.3 | 48 | 1.3 | 30 | 38 | 29 | 833 | 521 | Add |
| EH-716-60 | 60 | 56 | 33.3 | 60 | 1.3 | 30 | 50 | 29 | 1100 | 688 | Add |
| EH-716-72 | 72 | 56 | 33.3 | 72 | 1.3 | 30 | 62 | 29 | 1367 | 854 | Add |
| EH-716-96 | 93 | 56 | 33.3 | 93 | 1.3 | 30 | 86 | 29 | 1900 | 1188 | Add |
Demonstration/Classroom Fume Hoods |
|||||||||||
| EH-911-60 | 60 | 48 | 30 | 60 | 1.3 | 32 | 53 | 26.5 | 1030 | 722 | Add |
*Height of open sash; CFM calculated at 100 FPM **CFM@36"; CFM@72" |
|||||||||||
The EH-100 series airfoil-type fume hood features a 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom, which results in minimized turbulence and increased performance. Like the exterior of the hood, the airfoil is made from chemical-resistant, powder-coated, 16-gauge cold rolled steel. A stainless steel airfoil is available as an option. Posts are 5” (127 mm) wide.
The EH-200 series provides the same aerodynamic design features as the EH-100 airfoil hood series, with entrance from two sides. This makes it ideal for use in classroom or prep room settings or whenever demonstration of experiments is desired.
A 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom provide minimized turbulence and increased performance.
The EH-200 features standard 5” (127 mm) posts to allow for electrical and remote control plumbing services on both sides, and these can be configured to your exact specifications.
The EH-400 series, with a double-hung sash configuration and 72” high opening, is designed to accommodate a large-apparatus application, up to 85” in height. Posts are 5” (127 mm) wide.
The Eliminator 700 Perchloric Acid Hood has the same aerodynamic design as the 100 series, with a 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom to minimize turbulence and provide increased performance.
This hard-working hood also features a built-in trough to capture runoff in washdown procedures where perchloric acid is in use. In addition, there is a manual washdown feature for the areas behind the baffles as well as the duct-collar areas.
The interior is fabricated of type 316
stainless steel, integrally welded to a 316 stainless steel work surface, then buffed and polished to a #4 finish. The top is 1-1/4” with
a 1/4” dish to retain spills. The airfoil and sash are also made of 316 stainless steel.
The EH-900 series is an educational viewing fume hood with one slimmed down (2” or 51 mm) front post and one standard (5” or 127 mm) post to allow for more workspace and electrical services. Plumbing service must be deck mounted. The EH-900 is available in either right-hand or left-hand orientation. This hood features a two-sash configuration and a third (end) viewing window, making it ideal for use in high schools or any environment where demonstration of experiments is desired. The end window may be eliminated for through-wall installations.
©2006 GENEVA SCIENTIFIC ALL RIGHTS RESERVED | Internet Marketing by Atlantic BT