Hospital Pharmacy Isolator (Negative, Recirculation Pressure)

Barrier isolation system provide inherently superior sterility compared to open front clean air devices such as laminar flow clean benches and Class II biological safety cabinets. USP797 guidelines specify that isolators may be situated in an area subject to less severe environmental controls compared with open front clean air devices.

When used as part of a system that includes operator aseptic technique training, process validation, expiration setting, product quality maintenance after the CSP leaves the pharmacy, isolators are a cost-effective solution especially for lower-volume pharmacies. They reduce operating and renovation costs, take up less space, and are easier to maintain.

The negative pressure, recirculating HPI model is suitable for work involving hazardous materials, antineoplastic, or cytotoxic compounding applications. The work zone and pass-thru interchange are under negative pressure to the room in order to maintain operator protection in case of a breach in the barrier isolation system.

When hazardous drugs compounded have the potential to volatilize, the negative pressure, recirculating isolator should be ordered with the optional exhaust activated carbon filter and / or externally vented.

Alternatively, a negative pressure, total exhaust isolator should be selected.

Model GPI-4-NS GPI-6-NS
Add to Quotes Add to Quotes
External Dimensions Without Base Stand 52.8" x 32.3" x 51.9"
1340 x 820 x 1320 mm
76.8" x 32.3" x 51.9"
1950 x 820 x 1320 mm
With Base Stand (Min) 59.9" x 32.3" x 78.5"
1522 x 820 x 1995 mm
83.9" x 32.3" x 78.5"
2132 x 820 x 1995 mm
With Base Stand (Max) 59.9" x 32.3" x 88.6"
1522 x 820 x 2250 mm
83.9" x 32.3" x 88.6"
2132 x 820 x 2250 mm
Main Chamber Work Zone 33.1" x 24.0" x 26.4"
840 x 610 x 670 mm
57.1" x 24.0" x 26.4"
1450 x 610 x 670 mm
Pass Through 13.9" x 24.0" x 26.4"
355 x 610 x 670 mm
13.9" x 24.0" x 26.4"
355 x 610 x 670 mm
Work Zone and Interchange Chamber Performance ISO Class 3 (Class 1, Federal Standard 209E)
Inlet Filter Type 80% efficiency filter
Downflow and Exhaust Filter Type ULPA filter with integral metal guards and filter frame gaskets; fully compliant with EN 1822 (H14) and IEST-RP-CC001.3 requirements (each cabinet has individual downflow and exhaust filters)
Fluorescent Lamp Intensity > 950 Lux (> 88 foot candles)
Isolator Construction Main Body 1.2 mm (0.05") 18 gauge electrogalvanised steel with white oven-baked epoxy antimicrobial powder-coated finish
Work Tray 1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish
Side Walls 1.2 mm (0.05") 18 gauge stainless steel, type 304, with 4B finish

Maximum Patient Protection and Sterility

Robust construction and enhanced safety features qualify the Hospital Pharmacy Isolator for the most demanding laboratory applications. The isolator is fully assembled and ready to install and operate when shipped.

SentinelTM Microprocessor Control, Monitoring System

The Sentinel™ microprocessor-based control system supervises operation of all cabinet functions. Controls are configurable to meet user requirements. Features of the main control panel include:

Blower Efficiency

Airflow




Safety and Certification

Warranty

Accessories and Options

Hospital Pharmacy Isolator is available as a standard bench top unit. Additional accessories are available for further enhancement.

Validated Performance



Standards Compliances Cabinet Performance Air Quality Filtration Electrical Safety
CETA CAG-001-2005, USA
CETA CAG-002-2006, USA
USP Chapter 797, USA
ISO 14644.1, Class 3, Worldwide
JIS B9920, Class 3, Japan
JIS BS5295, Class 3, Japan
US Fed Std 209E, Class 1 USA
EN-1822, Europe
IEST-RP-CC001.3, USA
IEST-RP-CC007, USA
IEST-RP-CC034.1, USA
EN 61010-1, Europe
IEC 61010-1, Worldwide