Labconco 6′ Cell Logic Class II Type B2 Biological Safety Cabinet Model 323681102
with Temp-Zone™, UV Lamp, Service Fixture, Vacu-Pass Portals & Base Stand
The Labconco Cell Logic Class II Type B2 Biological Safety Cabinet provides maximum personnel, product, and environmental protection for laboratories working with hazardous particulates and biological agents requiring BSL-1 through BSL-4 containment.
As a Type B2 (100% Exhaust / Total Exhaust) BSC, this cabinet maintains a minimum average inflow velocity of 100 fpm through the sash opening and requires a dedicated exhaust system with a remote blower. All inflow and downflow air is HEPA-filtered and exhausted outside the laboratory, making this cabinet suitable for volatile chemical use as an adjunct to microbiological applications.
This model is purpose-built for cell research, featuring a modified sash design compatible with microscopy and a Temp-Zone™ temperature-controlled work area to support cell viability during extended procedures.
Containment & Airflow Design
- Cabinet Type: Class II, Type B2 (100% Exhaust)
- Airflow: HEPA-filtered downflow air drawn from lab; all air exhausted after filtration
- Recirculation: None (total exhaust design)
- Inflow Velocity: Minimum 100 fpm through sash opening
- Exhaust: Dedicated exhaust system with remote blower required
Filtration & Safety
- Supply & Exhaust Filters: 99.99+% efficient HEPA
- Optional Filters: 99.999% ULPA or H14 HEPA
- Negative Pressure Design: Intrinsically safe for hazardous operations
- All Contaminated Air: Passes through exhaust HEPA before discharge
Airflow Control & Monitoring
- Long-life DC Electronically Commutated Motor (ECM)
- BalanceFlow™ plenum for energy efficiency and ultra-quiet operation
- Constant Airflow Profile™ (CAP) airflow monitoring system
- Air-Wave™ Entry System to enhance containment at access opening
- Contain-Air™ negative pressure channel at top of sash
- Integrated airflow sensor displaying inflow and downflow on touchscreen
Work Area & Construction
- Work Surface: Removable, seamless Type 304 stainless steel, dished with lift-out knobs
- Temp-Zone™ Work Area:
- Temperature-controlled zone on left side of work surface
- Size: 10.5″ W × 12.0″ D (27 × 30 cm)
- Requires external water circulator (not included)
- Interior: Unitized, pressure-tested stainless steel
- Exterior: Optic White epoxy-coated steel
Sash, Lighting & Ergonomics
- 10° angled, fully closing sash
- 1/4″ tempered safety glass with counterbalanced, anti-racking mechanism
- Working Sash Height: 8″ (20.3 cm)
- Maximum Sash Opening: 22.5″ (57 cm)
- Viewing Height: 27.0″ (69 cm)
- Bright, glare-free LED lighting up to 180 foot-candles (1937 lux), located outside contaminated area
Standard Features Included
- UV lamp
- Service fixture (air, vacuum, etc.)
- Right and left Vacu-Pass™ portals
- Curved stainless steel inlet grille with waterfall design
- Reserve-Air™ secondary airflow slots
- Two electrical outlets with flush stainless steel covers and dampened hinges
- Airtight damper with 10″ (25.4 cm) nominal round connection
- Noise level: <67 dBA
- 10′ (3 m) power cord with plug
Temp-Zone™ Circulator Requirements (Not Included)
- Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
- Typical volume: 6 liters
- Operating temperature range: 0–50°C
- Chiller/heater system required
Applications
- Cell culture and tissue engineering
- Advanced microbiology and virology
- Microscopy-based biological research
- Work involving volatile chemicals with biological agents