322391102

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 22.5″ (57 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco Cell Logic Class II Type A2 Biological Safety Cabinet Model 322391102

3-Foot | Temp-Zone™ with UV Lamp, Service Fixture, Vacu-Pass™ Portals, and Base Stand

The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 322391102) is designed to provide personnel and product protection for biosafety level 1 through 4 applications, particularly where microscopy access or temperature-controlled work surfaces are required.

This 3-foot cabinet includes the Temp-Zone™ temperature-controlled work area, UV lamp, service fixture, Vacu-Pass™ portals, and a factory-installed base stand, providing a complete, ready-to-use laboratory solution.

Containment, Filtration & Exhaust

  • Cabinet Type: Class II, Type A2

  • Filtration: HEPA-filtered supply and exhaust air

  • Exhaust Options:

    • HEPA-filtered air returned to the laboratory

    • Optional canopy connection to a facility exhaust system

When canopy-connected, the cabinet safely accommodates minute quantities of volatile toxic chemicals and trace amounts of radionuclides.

Airflow Performance

  • Air Inflow Velocity: 105 fpm (0.53 m/sec)

  • Air Downflow Velocity: 55 fpm (0.28 m/sec)

Engineered to maintain uniform laminar airflow while ensuring containment integrity.

Temp-Zone™ Temperature-Controlled Work Area

  • Location: Left side of work surface

  • Size: 10.5″ W × 12.0″ D (27 × 30 cm)

  • Temperature Range: 0–50 °C

Water Circulator Required (Not Included):

  • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)

  • Typical volume: 6 liters

  • Chiller/heater required

Accessory Package

  • UV Lamp

  • Right-Side Service Fixture (air, vacuum, etc.)

  • Right and Left Vacu-Pass™ Portals for tubing and cable routing while maintaining containment

Dimensions & Physical Specifications

  • Nominal Width: 3 ft

  • Sash Opening Width: 22.5″ (57 cm)

Electrical Requirements

  • Voltage: 115V

  • Frequency: 60 Hz

  • Current: 16A

Compatible with standard North American laboratory electrical service.

Typical Applications

  • Microscopy-based research with temperature-sensitive samples

  • Cell culture and life sciences workflows requiring a Temp-Zone™ work area

  • Biosafety Level 1–4 laboratories (per institutional guidelines)

  • Labs requiring full accessory integration with a base stand

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Base Stand

Working Sash Height

, ,

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
322391102322391102
- +
Scroll to Top