342391002

$18,635.00

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 22.5” (57 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco Cell Logic Class II Type A2 Biological Safety Cabinet Model 342391002

3-Foot | Scope-Ready™ with Temp-Zone™, Service Fixture, and Vacu-Pass™ Portals

The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 342391002) provides personnel and product protection for biosafety level 1 through 4 applications requiring microscopy or temperature-controlled work areas.

This 3-foot configuration features the Scope-Ready™ package, Temp-Zone™ temperature-controlled work surface, UV lamp, service fixture, and Vacu-Pass™ portals, offering flexible installation for laboratories that already have a compatible base or custom casework.

Containment, Filtration & Exhaust Configuration

  • Cabinet Type: Class II, Type A2

  • Filtration: HEPA-filtered supply and exhaust air

  • Exhaust Options:

    • HEPA-filtered air returned to the laboratory

    • Optional canopy connection to a facility exhaust system

When canopy-connected, the cabinet is suitable for minute quantities of volatile toxic chemicals and trace amounts of radionuclides, per institutional safety guidelines.

Airflow Performance

  • Air Inflow Velocity: 105 fpm (0.53 m/sec)

  • Air Downflow Velocity: 55 fpm (0.28 m/sec)

Provides uniform laminar airflow across the work surface while maintaining containment integrity.

Scope-Ready™ Package

  • Sash Cutout: 7.0″ W × 10.5″ H (18 × 27 cm)

  • Pure-Vu™ Seal with powder-coated steel collar

Note: A Stand-Still™ Isolation Platform is required for microscopy applications and is sold separately.

Temp-Zone™ Temperature-Controlled Work Area

  • Location: Left side of work surface

  • Size: 10.5″ W × 12.0″ D (27 × 30 cm)

  • Temperature Range: 0–50 °C

Water Circulator Required (Not Included):

  • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)

  • Typical fluid volume: 6 liters

  • Chiller/heater required

Accessory Package

  • UV Lamp

  • Right-Side Service Fixture (air, vacuum, etc.)

  • Right and Left Vacu-Pass™ Portals for safe routing of tubing and cables without compromising containment

Dimensions & Physical Specifications

  • Nominal Width: 3 ft

  • Sash Opening Width: 22.5″ (57 cm)

Electrical Requirements

  • Voltage: 115V

  • Frequency: 60 Hz

  • Current: 16A

Standard North American laboratory electrical compatibility.

Typical Applications

  • Microscopy-based biological research

  • Temperature-sensitive workflows in BSL-1 through BSL-4 labs (per institutional approval)

  • Labs requiring Scope-Ready™ and Temp-Zone™ functionality without a base stand

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Base Stand

Working Sash Height

, ,

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
342391002342391002
$18,635.00
- +
Scroll to Top