Labconco Cell Logic Class II Type A2 Biological Safety Cabinet Model 342391002
3-Foot | Scope-Ready™ with Temp-Zone™, Service Fixture, and Vacu-Pass™ Portals
The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 342391002) provides personnel and product protection for biosafety level 1 through 4 applications requiring microscopy or temperature-controlled work areas.
This 3-foot configuration features the Scope-Ready™ package, Temp-Zone™ temperature-controlled work surface, UV lamp, service fixture, and Vacu-Pass™ portals, offering flexible installation for laboratories that already have a compatible base or custom casework.
Containment, Filtration & Exhaust Configuration
-
Cabinet Type: Class II, Type A2
-
Filtration: HEPA-filtered supply and exhaust air
-
Exhaust Options:
-
HEPA-filtered air returned to the laboratory
-
Optional canopy connection to a facility exhaust system
-
When canopy-connected, the cabinet is suitable for minute quantities of volatile toxic chemicals and trace amounts of radionuclides, per institutional safety guidelines.
Airflow Performance
-
Air Inflow Velocity: 105 fpm (0.53 m/sec)
-
Air Downflow Velocity: 55 fpm (0.28 m/sec)
Provides uniform laminar airflow across the work surface while maintaining containment integrity.
Scope-Ready™ Package
-
Sash Cutout: 7.0″ W × 10.5″ H (18 × 27 cm)
-
Pure-Vu™ Seal with powder-coated steel collar
Note: A Stand-Still™ Isolation Platform is required for microscopy applications and is sold separately.
Temp-Zone™ Temperature-Controlled Work Area
-
Location: Left side of work surface
-
Size: 10.5″ W × 12.0″ D (27 × 30 cm)
-
Temperature Range: 0–50 °C
Water Circulator Required (Not Included):
-
Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
-
Typical fluid volume: 6 liters
-
Chiller/heater required
Accessory Package
-
UV Lamp
-
Right-Side Service Fixture (air, vacuum, etc.)
-
Right and Left Vacu-Pass™ Portals for safe routing of tubing and cables without compromising containment
Dimensions & Physical Specifications
-
Nominal Width: 3 ft
-
Sash Opening Width: 22.5″ (57 cm)
Electrical Requirements
-
Voltage: 115V
-
Frequency: 60 Hz
-
Current: 16A
Standard North American laboratory electrical compatibility.
Typical Applications
-
Microscopy-based biological research
-
Temperature-sensitive workflows in BSL-1 through BSL-4 labs (per institutional approval)
-
Labs requiring Scope-Ready™ and Temp-Zone™ functionality without a base stand