Labconco Cell Logic Class II Type A2 Biosafety Cabinet Model 342391102
3-Foot | Scope-Ready™ with Temp-Zone™, Service Fixture, Vacu-Pass™ Portals, and Base Stand
The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 342391102) is designed to provide personnel and product protection for biosafety level 1 through 4 applications requiring microscopy access and temperature control of the work surface.
This 3-foot configuration includes the Scope-Ready™ package, Temp-Zone™ temperature-controlled work area, UV lamp, service fixture, Vacu-Pass™ portals, and a factory-matched base stand, delivering a complete, ready-to-install laboratory solution.
Containment, Filtration & Exhaust Configuration
-
Cabinet Type: Class II, Type A2
-
Filtration: HEPA-filtered supply and exhaust air
-
Exhaust Options:
-
HEPA-filtered air returned to the laboratory
-
Optional canopy connection to a facility exhaust system
-
When canopy-connected, this cabinet may handle minute quantities of volatile toxic chemicals and trace amounts of radionuclides, subject to institutional safety protocols.
Airflow Performance
-
Air Inflow Velocity: 105 fpm (0.53 m/sec)
-
Air Downflow Velocity: 55 fpm (0.28 m/sec)
Engineered for uniform laminar airflow across the work surface while maintaining containment integrity.
Scope-Ready™ Package
-
Sash Cutout: 7.0″ W × 10.5″ H (18 × 27 cm)
-
Pure-Vu™ Seal with powder-coated steel collar
Note: A Stand-Still™ Isolation Platform is required for microscope use and is sold separately.
Temp-Zone™ Temperature-Controlled Work Area
-
Location: Left side of work surface
-
Size: 10.5″ W × 12.0″ D (27 × 30 cm)
-
Temperature Range: 0–50 °C
Water Circulator Required (Not Included):
-
Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
-
Typical fluid volume: 6 liters
-
Chiller/heater required
Accessory Package
-
UV Lamp
-
Right-Side Service Fixture (air, vacuum, etc.)
-
Right and Left Vacu-Pass™ Portals for tubing and cable routing while maintaining containment
Dimensions & Physical Specifications
-
Nominal Width: 3 ft
-
Sash Opening Width: 22.5″ (57 cm)
Electrical Requirements
-
Voltage: 115V
-
Frequency: 60 Hz
-
Current: 16A
Compatible with standard North American laboratory electrical service.
Typical Applications
-
Microscopy-based biological research
-
Temperature-sensitive cell culture and life science workflows
-
BSL-1 through BSL-4 laboratories (per institutional approval)
-
Labs requiring Scope-Ready™ and Temp-Zone™ functionality with base stand
Need Help Choosing a Biological Safety Cabinet?
Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.
Contact us for a quote