342591102

$23,340.00

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 22.5” (57 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco Cell Logic Class II Type A2 Biosafety Cabinet

5-Foot | Scope-Ready™ with Temp-Zone™, UV Lamp, Service Fixture, Vacu-Pass™ Portals, and Base Stand
Model 342591102 | 115V / 60Hz, 16A

The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 342591102) delivers personnel and product protection for biosafety level 1 through 4 applications requiring microscopy access and temperature-controlled work surfaces.

This 5-foot cabinet is equipped with the Scope-Ready™ package, Temp-Zone™ temperature-controlled work area, UV light, service fixtures, Vacu-Pass™ portals, and a factory-supplied base stand, providing a complete, flexible containment solution for temperature-sensitive biological research.

Containment, Filtration & Exhaust Configuration

  • Cabinet Type: Class II, Type A2

  • Filtration: HEPA-filtered supply and exhaust air

  • Exhaust Options:

    • HEPA-filtered air exhausted back into the laboratory

    • Can be canopy-connected to a facility exhaust system

When canopy-connected, this cabinet is suitable for procedures involving small quantities of volatile toxic chemicals and trace amounts of radionuclides, following institutional safety guidelines.

Airflow Performance

  • Air Inflow Velocity: 105 fpm (0.53 m/sec)

  • Air Downflow Velocity: 55 fpm (0.28 m/sec)

These airflow rates ensure containment at the sash opening while maintaining uniform downward airflow across the work surface.

Scope-Ready™ Package

Designed for microscopy-based workflows:

  • Sash Cutout Dimensions: 7.0″ W × 10.5″ H (18 × 27 cm)

  • Pure-Vu™ Seal with powder-coated steel collar

  • Supports microscope integration while maintaining containment

Note: A Stand-Still™ Isolation Platform is required for microscope use and is sold separately.

Temp-Zone™ Temperature-Controlled Work Area

Supports temperature-sensitive procedures:

  • Work Area Dimensions: 10.5″ W × 12.0″ D (27 × 30 cm)

  • Location: Left side of the work surface

  • Water Circulator Required (Not Included)

Circulator Requirements:

  • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)

  • Typical volume: 6 liters

  • Operating temperature range: 0–50 °C (chiller/heater)

Accessory Package

  • UV Light

  • Right-Side Service Fixture (Air, vacuum, etc.)

  • Right and Left Vacu-Pass™ Portals for safe routing of cords, tubing, or cables

Dimensions & Physical Specifications

  • External Dimensions: 66.4″ W × 32″ D × 61.9″ H

  • Nominal Width: 5 ft

  • Sash Opening: 9″

  • Working Sash Heights: 8″, 10″, 12″

  • Base Stand: Included

Electrical Requirements

  • Voltage: 115V

  • Frequency: 60 Hz

  • Current: 16A

Designed for standard North American laboratory electrical service.

Typical Applications

  • Biosafety workflows requiring temperature-controlled work surfaces

  • Cell culture and biological research procedures

  • Laboratory procedures requiring microscopy access and utility integration

  • BSL-1 through BSL-4 research (subject to institutional approval and configuration)

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Base Stand

Sash Opening

Working Sash Height

, ,

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
342591102342591102
$23,340.00
- +
Scroll to Top