322591102

$21,055.00

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 22.5” (57 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco Cell Logic Class II Type A2 Biological Safety Cabinet

5-Foot | Temp-Zone™ with UV Lamp, Service Fixture, Vacu-Pass™ Portals, and Base Stand
Model 322591102 | 115V / 60Hz, 16A

The Labconco Cell Logic Class II Type A2 Biological Safety Cabinet (Model 322591102) provides personnel and product protection for biosafety level 1 through 4 applications requiring microscopy or temperature-controlled work surfaces.

This 5-foot cabinet is configured with the Temp-Zone™ temperature-controlled work area, UV light, service fixtures, Vacu-Pass™ portals, and a factory-supplied base stand, delivering a flexible and complete containment solution for temperature-sensitive laboratory workflows.

Containment, Filtration & Exhaust Configuration

  • Cabinet Type: Class II, Type A2

  • Filtration: HEPA-filtered supply and exhaust air

  • Exhaust Options:

    • HEPA-filtered air exhausted into the laboratory

    • Can be canopy-connected to a facility exhaust system

When canopy-connected, this cabinet is suitable for procedures involving small quantities of volatile toxic chemicals and trace amounts of radionuclides, in compliance with institutional safety guidelines.

Airflow Performance

  • Air Inflow Velocity: 105 fpm (0.53 m/sec)

  • Air Downflow Velocity: 55 fpm (0.28 m/sec)

These airflow rates maintain containment at the sash opening while ensuring uniform downflow across the work surface.

Temp-Zone™ Temperature-Controlled Work Area

Supports temperature-sensitive procedures:

  • Work Area Dimensions: 10.5″ W × 12.0″ D (27 × 30 cm)

  • Location: Left side of the work surface

  • Water Circulator Required (Not Included)

Circulator Requirements:

  • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)

  • Typical fluid volume: 6 liters

  • Operating temperature range: 0–50 °C (chiller/heater)

Accessory Package

  • UV Light

  • Right-Side Service Fixture (Air, vacuum, etc.)

  • Right and Left Vacu-Pass™ Portals for safe routing of cords, tubing, or cables

Dimensions & Physical Specifications

  • External Dimensions: 66.4″ W × 32″ D × 61.9″ H

  • Nominal Width: 5 ft

  • Sash Opening: 9″

  • Working Sash Heights: 8″, 10″, 12″

  • Base Stand: Included

Electrical Requirements

  • Voltage: 115V

  • Frequency: 60 Hz

  • Current: 16A

Compatible with standard North American laboratory electrical service.

Typical Applications

  • Biosafety workflows requiring temperature-controlled work surfaces

  • Cell culture and biological research procedures

  • Laboratory procedures requiring microscopy or controlled temperature integration

  • BSL-1 through BSL-4 research (subject to institutional approval and configuration)

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Base Stand

Sash Opening

Working Sash Height

, ,

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
322591102322591102
$21,055.00
- +
Scroll to Top