Labconco Cell Logic Class II Type A2 Biological Safety Cabinet Model 322591002
5-Foot | Temp-Zone™ with UV Lamp, Service Fixture, and Vacu-Pass™ Portals
The Labconco Cell Logic Class II Type A2 Biological Safety Cabinet (Model 322591002) is designed to provide personnel and product protection for biosafety level 1 through 4 applications requiring a temperature-controlled work surface.
This 5-foot cabinet is configured with the Temp-Zone™ temperature-controlled work area, UV lamp, service fixtures, and Vacu-Pass™ portals, making it well suited for temperature-sensitive biological workflows where external microscope integration is not required.
Containment, Filtration & Exhaust Configuration
-
Cabinet Type: Class II, Type A2
-
Filtration: HEPA-filtered supply and exhaust air
-
Exhaust Options:
-
HEPA-filtered air exhausted back into the laboratory
-
Can be canopy-connected to a facility exhaust system
-
When canopy-connected, this cabinet may be used for procedures involving minute quantities of volatile toxic chemicals and trace radionuclides, subject to institutional safety approval.
Airflow Performance
-
Air Inflow Velocity: 105 fpm (0.53 m/sec)
-
Air Downflow Velocity: 55 fpm (0.28 m/sec)
These airflow values support effective containment while maintaining consistent laminar downflow across the work area.
Temp-Zone™ Temperature-Controlled Work Area
Designed for precision temperature control during sensitive procedures:
-
Work Area Size: 10.5″ W × 12.0″ D (27 × 30 cm)
-
Location: Left side of the work surface
-
Water Circulator Required (Not Included)
Circulator Requirements:
-
Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
-
Typical volume: 6 liters
-
Operating temperature range: 0–50 °C (chiller/heater)
Accessory Package
-
UV Lamp
-
Right-Side Service Fixture (air, vacuum, etc.)
-
Right and Left Vacu-Pass™ Portals for routing cords, tubing, or cables while maintaining containment
Dimensions & Physical Specifications
-
Nominal Width: 5 ft
-
Sash Opening Width: 22.5″ (57 cm)
-
Base Stand: Not included
Electrical Requirements
-
Voltage: 115V
-
Frequency: 60 Hz
-
Current: 16A
Compatible with standard North American laboratory electrical infrastructure.
Typical Applications
-
Temperature-sensitive biosafety workflows
-
Cell culture and biological research
-
Procedures requiring integrated utilities and controlled thermal conditions
-
BSL-1 through BSL-4 laboratory environments (per institutional protocols)