Labconco Cell Logic Class II Type A2 Biosafety Cabinet
Scope-Ready™ with Temp-Zone™ Service Fixture & Vacu-Pass™ Portals
Model 342691002 | 6-Foot Biosafety Cabinet | 115V / 60Hz
The Labconco Cell Logic Class II Type A2 Biosafety Cabinet (Model 342691002) is designed to provide personnel and product protection for biosafety level 1 through 4 applications that require microscopy access and/or temperature control of the work surface.
This 6-foot cabinet is equipped with Scope-Ready™, Temp-Zone™, and Vacu-Pass™ packages, making it well-suited for specialized laboratory workflows involving microscopes, temperature-sensitive samples, and external equipment connections.
Containment, Filtration & Exhaust Configuration
-
Cabinet Type: Class II, Type A2
-
Filtration: HEPA-filtered supply and exhaust air
-
Exhaust Options:
-
Exhausts HEPA-filtered air back into the laboratory
-
Can be canopy-connected to a facility exhaust system
-
When canopy-connected, the Cell Logic BSC may be used for applications involving minute quantities of volatile toxic chemicals and trace amounts of radionuclides, in accordance with institutional safety protocols.
Airflow Performance
-
Air Inflow Velocity: 105 fpm (0.53 m/sec)
-
Air Downflow Velocity: 55 fpm (0.28 m/sec)
These airflow characteristics support containment at the sash opening while maintaining downward airflow across the work surface for sample protection.
Scope-Ready™ Package
Designed to support microscopy-based workflows:
-
Sash Cutout: 7.0″ W × 10.5″ H (18 × 27 cm)
-
Pure-Vu™ Seal with powder-coated steel collar
-
Enables microscope integration without compromising cabinet containment
Note: A Stand-Still™ Isolation Platform is required for microscope use and is sold separately.
Temp-Zone™ Temperature-Controlled Work Area
Supports temperature-sensitive procedures:
-
Temperature-Controlled Zone: 10.5″ W × 12.0″ D (27 × 30 cm)
-
Located on the left side of the work surface
-
Water Circulator Required (Not Included)
Circulator Requirements:
-
Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
-
Typical fluid volume: 6 liters
-
Operating temperature range: 0–50 °C (chiller/heater)
Accessory Package
This configuration includes:
-
UV Light
-
Right-Side Service Fixture
(Air, vacuum, or other laboratory utilities) -
Right and Left Vacu-Pass™ Portals
For safe routing of cords, cables, and tubing without disrupting airflow
Dimensions & Physical Specifications
-
External Dimensions: 78.4″ W × 32″ D × 61.9″ H
-
Nominal Width: 6 ft
-
Sash Opening: 9″
-
Working Sash Heights: 8″, 10″, or 12″
-
Base Stand: Not included (must be ordered separately)
Electrical Requirements
-
Voltage: 115V
-
Frequency: 60Hz
Designed for standard North American laboratory electrical service.
Typical Applications
-
Biosafety workflows requiring microscopy access
-
Procedures involving temperature-sensitive samples
-
Cell culture and research requiring external equipment integration
-
BSL-1 through BSL-4 applications (subject to institutional approval and configuration)
Need Help Choosing a Biological Safety Cabinet?
Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.
Contact us for a quote


