Labconco Cell Logic Class II Type A2 Biological Safety Cabinet
Temp-Zone™ with UV Lamp, Service Fixture, Vacu-Pass™ Portals, and Base Stand
Model 322691102 | 6-Foot Biosafety Cabinet | 115V / 60Hz
The Labconco Cell Logic Class II Type A2 Biological Safety Cabinet (Model 322691102) provides personnel and product protection for biosafety level 1 through 4 applications that require temperature control of the work surface and integration of laboratory utilities.
This 6-foot cabinet is configured with the Temp-Zone™ package, UV light, service fixtures, Vacu-Pass™ portals, and a factory-supplied base stand, delivering a complete containment solution for temperature-sensitive biological workflows.
Containment, Filtration & Exhaust Configuration
-
Cabinet Type: Class II, Type A2
-
Filtration: HEPA-filtered supply and exhaust air
-
Exhaust Options:
-
HEPA-filtered air exhausted back into the laboratory
-
Can be canopy-connected to a facility exhaust system
-
When canopy-connected, the Cell Logic BSC may be used for applications involving minute quantities of volatile toxic chemicals and trace amounts of radionuclides, in accordance with institutional safety protocols.
Airflow Performance
-
Air Inflow Velocity: 105 fpm (0.53 m/sec)
-
Air Downflow Velocity: 55 fpm (0.28 m/sec)
These airflow characteristics support containment at the sash opening while maintaining consistent downflow across the work surface.
Temp-Zone™ Temperature-Controlled Work Area
Designed for temperature-sensitive procedures:
-
Temperature-Controlled Zone Dimensions: 10.5″ W × 12.0″ D (27 × 30 cm)
-
Location: Left side of the work surface
-
Water Circulator Required: Not included
Circulator Requirements:
-
Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
-
Typical fluid volume: 6 liters
-
Operating temperature range: 0–50 °C (chiller/heater)
Accessory Package
This configuration includes:
-
UV Light
-
Right-Side Service Fixture
(Air, vacuum, or other laboratory utilities) -
Right and Left Vacu-Pass™ Portals
For routing cords, tubing, and cables through the cabinet sidewalls without disrupting airflow
Dimensions & Physical Specifications
-
External Dimensions: 78.4″ W × 32″ D × 61.9″ H
-
Nominal Width: 6 ft
-
Sash Opening: 9″
-
Working Sash Heights: 8″, 10″, or 12″
-
Base Stand: Included
Electrical Requirements
-
Voltage: 115V
-
Frequency: 60Hz
Compatible with standard North American laboratory electrical service.
Typical Applications
-
Biosafety workflows requiring temperature-controlled work surfaces
-
Cell culture and biological research procedures
-
Applications requiring utility connections and external equipment integration
- BSL-1 through BSL-4 laboratory work (subject to institutional approval and configuration)
Need Help Choosing a Biological Safety Cabinet?
Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.
Contact us for a quote