Biological Incubator Model I-30NL
Applications
Designed for applications such as B.O.D. determinations, culturing, rearing and holding of test organisms as well as bioassays, and product stability testing.
Percival’s IntellusUltra Controller
Percival Scientific has built a reputation of providing flexible, customized options for research scientists around the world. We have taken the philosophy to the next level with our improved IntellusUltra Controller. Now choose from the levels of functionality that meet your needs.
Lighting System
- No lights are contained inside the chamber
Cabinet Construction
- Interior constructed of 22-gauge electro-zinc plated steel
- Exterior constructed of 18-gauge exterior electro-zinc plated steel
- Welded seams and joints on outer and inner shells
- Inner shell supported by non-compressing/non-thermal conducting material locking inner liner in place without a metal-to-metal bond to outer case
- Chamber is completely self-contained, suitable for stacking one above the other0
- Overall wall thickness is 2”
Insulation
- Woodless construction using CFC free insulation (overall wall thickness is 2”, ample insulation for maintenance of stated temperature range)
Door
- One door opening 26.8” x 29.6” provides full access to chamber interior (magnetic gasket provides a tight seal to door frame)
Shelving
- Three tiers of white epoxy coated steel wire shelving (each shelf is 16.4”D x 26.5”W)
- Shelves are supported by shelf clips allowing 1/2” vertical adjustments
- Maximum clearance between shelves is 8.5” per tier with all three shelves installed
Finish
- Interior and exterior painted with high reflective, environmentally friendly, high temperature baked white powder coating
Refrigeration
- Self-contained air-cooled condensing unit with hot gas bypass system for continuous compressor operation, extended life and close temperature control (this continuous running condensing unit ensures precise temperature control by alternating cycling refrigerant and hot gas to coil; this also prolongs life of compressor, and eliminates risk of ice buildup in coil)
- Solenoid valves have extended stem for quiet and long life operation
- Rear chamber wall mounted evaporator coil incorporates an air circulation fan (heat rejection to ambient with standard chamber: 3000 BTU/hr)
Temperature Safety Limit Controls
- Experiment Protection: Adjustable high and low temperature controls, audible alarms, and visual indicators provided
- Controls shut down all power to chamber, activating alarms (when the temperature returns to the normal range the system will automatically reset)
Convenience Receptacles
- One 115/1/60 convenience receptacle provided inside chamber
Options
- Additive Humidity Control with Sensor
- Dehumidifier with Sensor
- IntellusUltra Connect
- Android-Based Touch Screen
- CO2 Enrichment Package
- Self-Contained Water-Cooled Condensing Unit
- Dry Alarm Contacts
- Please contact us for more optional items