342491002

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 22.5” (57 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco Cell Logic Class II Type A2 Biosafety Cabinet Model 342491002

4-Foot | Scope-Ready™ with Temp-Zone™, UV Lamp, Service Fixture, and Vacu-Pass™ Portals

The Labconco Cell Logic Class II Type A2 Biological Safety Cabinet (Model 342491002) provides personnel and product protection for biosafety level 1 through 4 applications that require microscopy access and a temperature-controlled work surface within a compact 4-foot footprint.

This configuration combines the Scope-Ready™ package with the Temp-Zone™ temperature-controlled work area, along with UV lighting, service fixtures, and Vacu-Pass™ portals, offering advanced functionality for space-constrained laboratories.

Containment, Filtration & Exhaust Configuration

  • Cabinet Type: Class II, Type A2

  • Filtration: HEPA-filtered supply and exhaust air

  • Exhaust Options:

    • HEPA-filtered air exhausted back into the laboratory

    • Can be canopy-connected to a facility exhaust system

When canopy-connected, this cabinet may be used for applications involving minute quantities of volatile toxic chemicals and trace radionuclides, in accordance with institutional safety requirements.

Airflow Performance

  • Air Inflow Velocity: 105 fpm (0.53 m/sec)

  • Air Downflow Velocity: 55 fpm (0.28 m/sec)

These airflow values maintain containment at the sash opening while delivering uniform laminar downflow across the work area.

Scope-Ready™ Package

Designed for microscopy-based workflows:

  • Sash Cutout: 7.0″ W × 10.5″ H (18 × 27 cm)

  • Pure-Vu™ Seal with powder-coated steel collar

  • Maintains containment while accommodating microscope optics

Note: A Stand-Still™ Isolation Platform is required for microscope use and is sold separately.

Temp-Zone™ Temperature-Controlled Work Area

Supports temperature-sensitive procedures:

  • Work Area Size: 10.5″ W × 12.0″ D (27 × 30 cm)

  • Location: Left side of the work surface

  • Water Circulator Required (Not Included)

Circulator Requirements:

  • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)

  • Typical volume: 6 liters

  • Operating temperature range: 0–50 °C (chiller/heater)

Accessory Package

  • UV Lamp

  • Right-Side Service Fixture (air, vacuum, etc.)

  • Right and Left Vacu-Pass™ Portals for routing cords and tubing while maintaining containment

Dimensions & Physical Specifications

  • Nominal Width: 4 ft

  • Sash Opening Width: 22.5″ (57 cm)

  • Base Stand: Not included

Electrical Requirements

  • Voltage: 115V

  • Frequency: 60 Hz

  • Current: 16A

Compatible with standard North American laboratory electrical service.

Typical Applications

  • Biosafety workflows requiring microscopy and temperature control

  • Cell culture and biological research

  • Laboratories needing advanced features in a compact cabinet

  • BSL-1 through BSL-4 environments (per institutional approval)

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Base Stand

Sash Opening

Working Sash Height

, ,

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
342491002342491002
- +
Scroll to Top