Labconco 4′ Cell Logic Class II Type B2 Biological Safety Cabinet Model 323481002
With Temp-Zone™, UV Lamp, Service Fixture & Vacu-Pass™ Portals
The Labconco Cell Logic Class II Type B2 Biological Safety Cabinet (Model 323481002) provides comprehensive protection for personnel, products, and the environment from hazardous biological particulates, including BSL-1 through BSL-4 agents.
As a Type B2 cabinet, it draws HEPA-filtered air from the laboratory and exhausts 100% of inflow and downflow air externally. Because there is no recirculation, it is ideal for cell research and microbiological applications involving volatile chemicals, when used with a dedicated exhaust system and remote blower.
This configuration includes a Temp-Zone™ temperature-controlled work area, UV lamp, service fixture, and Vacu-Pass™ portals, offering a ready-to-use solution for sensitive cell culture workflows.
Airflow & Containment
- Cabinet Class: Class II, Type B2
- Minimum Inflow Velocity: 100 fpm through sash opening
- Airflow Pattern: Downflow HEPA-filtered air; all contaminated air exhausted
- Air Recirculation: None
- Exhaust Requirements: Dedicated exhaust system and remote blower
Filtration & Safety
- Supply & Exhaust HEPA Filters: 99.99+% efficient
- Optional Filters: 99.999% ULPA or H14 HEPA
- Airflow Monitoring: Constant Airflow Profile™ (CAP) with inflow/downflow display
- Negative Pressure Design: Intrinsically safe for chemical use
Performance & Airflow Control
- Long-life DC Electronically Commutated Motor (ECM)
- BalanceFlow™ plenum for ultra-quiet, energy-efficient operation
- Air-Wave™ Entry System enhances containment at access opening
- Contain-Air™ negative pressure channel at top of sash
Work Area & Construction
- Work Surface: Removable, seamless Type 304 stainless steel, dished with lift-out knobs
- Interior: Unitized, pressure-tested stainless steel
- Exterior: Optic White epoxy-coated steel
- Lighting: Bright, glare-free LED up to 180 foot-candles (1937 lux) outside the work area
Sash & Viewing
- Sash: 10° angled, fully closing, 1/4″ tempered safety glass
- Mechanism: Counterbalanced, anti-racking, easy-to-lift
- Maximum Sash Opening: 22.5″ (57 cm)
- Viewing Height: 27.0″ (69 cm)
Included Features (This Model)
- Temp-Zone™ Temperature-Controlled Work Area
- 10.5″ W × 12.0″ D (27 × 30 cm), left side of work surface
- Water circulator required (not included)
- UV Lamp
- Service Fixture (Air, Vacuum, etc.)
- Right & Left Vacu-Pass™ Portals
- Two Electrical Outlets with flush stainless steel covers and dampened hinges
- Logic OS with 5″ interior-mounted, line-of-sight touchscreen display
- Curved Stainless Steel Inlet Grille with waterfall design
- Reserve-Air™ Secondary Airflow Slots
- Airtight Damper: 10″ (25.4 cm) nominal round connection
- Noise Level: <67 dBA
- 10′ (3 m) Power Cord with Plug
Temp-Zone™ Circulator Requirements (Not Included)
- Flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
- Typical volume: 6 liters
- Temperature: 0–50°C
- External chiller/heater required
Applications
- Cell culture & tissue engineering
- Temperature-sensitive biological workflows
- Microbiology with volatile chemical use
- High-containment research
Need Help Choosing a Biological Safety Cabinet?
Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.
Contact us for a quote