343481102

$28,335.00

Labconco

105 fpm (0.53 m/sec)

55 fpm (0.28 m/sec)

Sash 8″ (20 cm)

- +
Call Now for Best Price.
262-245-1500 | Email

Labconco 4′ Cell Logic Class II Type B2 Biological Safety Cabinet Model 343481102

Scope-Ready with Temp-Zone™, Service Fixture, Vacu-Pass™ Portals & Base Stand

The Labconco Cell Logic Class II Type B2 Biological Safety Cabinet is engineered to provide maximum personnel, product, and environmental protection when working with hazardous biological particulates, including applications requiring BSL-1 through BSL-4 containment.

Class II Type B2 biosafety cabinets—also known as 100% Exhaust or Total Exhaust BSCs—maintain a minimum average inflow velocity of 100 feet per minute (fpm) through the sash opening and require a dedicated exhaust system with a remote blower. All inflow and downflow air is HEPA-filtered and exhausted from the laboratory, making this cabinet appropriate for volatile chemical use as an adjunct to microbiological work.

Designed specifically for cell research, Cell Logic Type B2 cabinets feature a modified sash compatible with microscopy and a Temp-Zone™ temperature-controlled work area to help maintain cell viability during sensitive procedures.

Airflow & Containment Design

  • Cabinet Type: Class II, Type B2 (100% Exhaust)
  • Minimum Inflow Velocity: 100 fpm
  • Airflow Pattern: HEPA-filtered downflow with total exhaust
  • Air Recirculation: None
  • Exhaust Requirement: Dedicated exhaust system with remote blower

Filtration & Safety

  • Supply & Exhaust Filters: 99.99+% efficient HEPA
  • Optional Filters: 99.999% efficient ULPA or H14 HEPA
  • Design: Intrinsically safe negative-pressure cabinet
  • Contaminated Air Handling: All air passes through exhaust HEPA before discharge

Airflow Control & Monitoring

  • Long-life DC Electronically Commutated Motor (ECM)
  • BalanceFlow™ plenum for energy efficiency and ultra-quiet operation
  • Constant Airflow Profile™ (CAP) airflow monitoring system
  • Air-Wave™ Entry System to enhance containment at the access opening
  • Contain-Air™ negative pressure channel at top of sash
  • Integrated airflow sensor displaying inflow and downflow values

Work Area & Construction

  • Work Surface: Removable, seamless Type 304 stainless steel, dished with lift-out knobs
  • Temp-Zone™ Temperature-Controlled Area:
    • Located on left side of work surface
    • Size: 10.5″ W × 12.0″ D (27 × 30 cm)
    • External water circulator required (not included)
  • Interior: Unitized, pressure-tested stainless steel
  • Exterior: Optic White epoxy-coated steel

Sash, Visibility & Lighting

  • 10° angled, fully closing sash
  • 1/4″ tempered safety glass
  • Counterbalanced, anti-racking, easy-lift mechanism
  • Maximum Sash Opening: 22.5″ (57 cm)
  • Viewing Height: 27.0″ (69 cm)
  • Bright, glare-free LED lighting up to 180 foot-candles (1937 lux)
  • Lighting located outside the contaminated work area

Included Standard Features

  • Base stand
  • Service fixture (air, vacuum, etc.)
  • Right and left Vacu-Pass™ portals
  • Scope-Ready™ sash configuration
  • Curved stainless steel inlet grille with waterfall design
  • Reserve-Air™ secondary airflow slots
  • Two electrical outlets with flush stainless steel covers and dampened hinges
  • Airtight damper with 10″ (25.4 cm) nominal round connection
  • Noise level: <67 dBA
  • 10′ (3 m) power cord with plug

Optional Packages & Accessories

  • Accessory Package
    • UV light
    • Additional service fixtures
    • Additional Vacu-Pass™ portals
  • Scope-Ready™ Package Details
    • 7.0″ W × 10.5″ H (18 × 27 cm) sash cutout
    • Pure-Vu™ seal with powder-coated steel collar
    • Stand-Still™ Isolation Platform required (sold separately)
  • Temp-Zone™ Circulator Requirements (not included)
    • Minimum flow rate: 0.4–0.5 GPM (1.5–1.9 LPM)
    • Typical volume: 6 liters
    • Temperature range: 0–50 °C
    • Chiller/heater required

Applications

  • Cell culture and tissue engineering
  • Microscopy-based biological research
  • Virology and advanced microbiology
  • Biological work involving volatile chemicals

Need Help Choosing a Biological Safety Cabinet?

Selecting the right biosafety cabinet depends on your workflow, biosafety level, lab layout, and certification requirements. Geneva Scientific’s experts can help you compare models, identify accessory options, and ensure the best fit for your needs.

Contact us for a quote

Manufacturer

External Dimensions

Sash Opening

Base Stand

Air Inflow Velocity

Air Downflow Velocity

Nominal Width

Shopping Cart
343481102343481102
$28,335.00
- +
Scroll to Top